Appendix
COMMAND DESCRIPTION
2 14089876543
3
4 6313551
5
6 4258513
7
8 16126313550
9 12138880123
@CONFIG Start ConfigMenu
Starts TAs internal configuration utility, which you can then use to customize the TAs
configuration for your particular application. You must enter the command while in your
communication programs terminal mode.
@P3=n Parity at Power Up
n = 04
Default: @P3=4 (none)
Use only to set the type of parity the TA uses when turned on. Once the TA receives an AT
command from the computer, it automatically adjusts to parity the computer is using.
@P3=0 Odd
@P3=1 Even
@P3=2 Mark
@P3=3 Space
@P3=4 None
@P4=n Data Bits
n = 7 or 8
Default: @P4=8 (8 data bits)
Use only to set the number of data bits TA uses when turned on. Once the TA receives an
AT command from the computer, it automatically adjusts to number of data bits the
computer is using.
@P4=7 7 data bits
@P4=8 8 data bits
@P6=n Stop Bits
n = 1 or 2
Default: @P6=1 (1 stop bit)
Use only to set the number of stop bits the TA uses when turned on. Once the TA receives
an AT command from the computer, it automatically adjusts to the number of stop bits the
computer is using.
@P6=1 1 stop bit
@P6=2 2 stop bits